Fortinet FortiGate 50A User Manual Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 272
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
58 Fortinet Inc.
Changing the FortiGate firmware System status
To use the following procedure you must have a TFTP server that the FortiGate unit
can connect to.
To revert to a previous firmware version using the CLI
1 Make sure that the TFTP server is running.
2 Copy the new firmware image file to the root directory of the TFTP server.
3 Log into the FortiGate CLI as the admin administrative user.
4 Make sure the FortiGate unit can connect to the TFTP server.
You can use the following command to ping the computer running the TFTP server.
For example, if the TFTP server's IP address is 192.168.1.168:
execute ping 192.168.1.168
5 Enter the following command to copy the firmware image from the TFTP server to the
FortiGate unit:
execute restore image <name_str> <tftp_ip>
Where <name_str> is the name of the firmware image file on the TFTP server and
<tftp_ip> is the IP address of the TFTP server. For example, if the firmware image
file name is FGT_300-v250-build045-FORTINET.out and the IP address of the
TFTP server is 192.168.1.168, enter:
execute restore image FGT_300-v250-build045-FORTINET.out
192.168.1.168
The FortiGate unit uploads the firmware image file. After the file uploads, a message
similar to the following is displayed:
Get image from tftp server OK.
This operation will downgrade the current firmware version!
Do you want to continue? (y/n)
6 Type Y.
7 The FortiGate unit reverts to the old firmware version, resets the configuration to
factory defaults, and restarts. This process takes a few minutes.
8 Reconnect to the CLI.
9 To confirm that the new firmware image has been loaded, enter:
get system status
10 Restore your previous configuration. Use the following command:
execute restore config
11 Update antivirus and attack definitions. For information, see “Manually initiating
antivirus and attack definitions updates” on page 75, or from the CLI, enter:
execute updatecenter updatenow
Note: Installing firmware replaces the current antivirus and attack definitions with the definitions
included with the firmware release that you are installing. After you install new firmware, use the
procedure “Manually initiating antivirus and attack definitions updates” on page 75 to make sure
that antivirus and attack definitions are up to date. You can also use the CLI command
execute updatecenter updatenow to update the antivirus and attack definitions.
Page view 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 271 272

Comments to this Manuals

No comments